How is travel distance measured within a floor area in Ontario?
Travel distance is measured along the actual walking path from the most remote point in a room or suite to the nearest egress doorway or exit, around fixed obstructions, not as a straight line, and it limits suite depth and layout flexibility.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
Designers often check only the corridor-to-exit distance and miss the in-suite leg. Measurement rules matter: in open floor plates you may measure with allowances for future partitions, and where a suite is separated from the corridor by a rated fire separation, travel distance to the exit can sometimes be measured from the suite door rather than the remote point. Document your measurement basis on life safety plans, since examiners frequently challenge the assumed path.
The Code cares about how far someone must actually walk to escape, weaving around desks and walls, not the straight-line distance. If the farthest corner is too far from a door, the layout needs another way out.