How long can a dead-end corridor be under the Ontario Building Code?
A dead-end public corridor is generally limited to 6 m (about 20 ft), because occupants trapped past the last cross-corridor or exit must be able to retreat quickly. Longer dead ends require redesign or a second egress route.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
Dead ends most often appear late in design when suite layouts shift and a corridor end loses its exit stair connection. Measure from the point where two-way travel is lost to the farthest point of the corridor. Fixes include relocating a stair, adding a cross-corridor connection, converting the dead end into suite space, or providing an exterior egress door. Care, treatment and detention occupancies have stricter expectations, so verify occupancy-specific provisions.
A hallway that ends without an exit is a trap in a fire, so the Code limits these dead ends to about 6 m. Beyond that, the layout must give people a second direction to escape.