OBC DIVISION B · PART 3 · SECTION 3.3 — SAFETY WITHIN FLOOR AREAS

How do you calculate occupant load under the Ontario Building Code?

Occupant load is the floor area divided by the area-per-person factor in Table 3.1.17.1, for example 0.75 m2 per person for assembly space with non-fixed seats, 1.85 m2 for classrooms and 9.3 m2 for offices, or the actual number of fixed seats.

Code reference
The occupant load of a floor area is based on the number of seats for fixed seating, or otherwise on tabulated square metres per person for each use, applied to the area of each room or space. A different load may be accepted where the design demonstrates the space will serve fewer or more persons.
OBC Division B, Subsection 3.1.17.

Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.

What this means in practice

Occupant load drives exit width, number of egress doorways, door swing, panic hardware, fire alarm triggers and washroom counts, so calculate it room by room rather than for the gross floor. Use net use-specific areas per the table factors and sum them along egress paths, remembering converging streams at exits. Restaurants and event spaces are frequent trouble spots, and posted occupant load signs are required for some assembly uses.

Plain language

The Code estimates how many people can fill a space by dividing its area by a standard amount of room per person, tighter for a banquet hall, roomier for an office. That head count then sizes the doors, hallways and exits.