PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code

3.3.1.5.Egress Doorways

(1) Except for dwelling units, a minimum of 2 egress doorways located so that one doorway could provide egress from the room or suite as required by Article 3.3.1.3. if the other doorway becomes inaccessible to the occupants due to a fire that originates in the room or suite, shall be provided for every room and every suite (a) whose area is more than 15 m2 and is used for (i) a high-hazard industrial occupancy, or (ii) a hazardous room, (b) intended for an occupant load more than 60, (c) in a floor area that is not sprinklered throughout and (i) the area of a room or suite is more than the value in Table 3.3.1.5.-A, or (ii) the travel distance within the room or suite to the nearest egress doorway, is more than the value in Table 3.3.1.5.-A, (d) in a floor area that is sprinklered throughout and does not contain a high-hazard industrial occupancy and (i) the travel distance to an egress doorway is more than 25 m, or (ii) the area of the room or suite is more than the value in Table 3.3.1.5.-B, or (e) where the area of the room is more than 100 m 2 and it is a hazardous classroom in elementary or secondary school. (2) Where 2 egress doorways are required by Sentence (1), they shall be placed at a distance from one another equal to or greater than one third of the maximum overall diagonal dimension of the area to be served, measured as the shortest distance that smoke would have to travel between the nearest required egress doors. Table 3.3.1.5.-A Egress in Floor Area Not Sprinklered Throughout Forming Part of Sentence 3.3.1.5.(1) Occupancy of Room or Suite Maximum Area of Room or Suite, m2 Maximum Distance to Egress Doorway, m Group A 150 15 Group C 100(1) 15(1) Group D 200 25 Group E 150 15 Group F, Division 2 150 10 Group F, Division 3 200 15 Notes to Table 3.3.1.5.-A: (1) See Article 3.3.4.4. for dwelling units. Table 3.3.1.5.-B Egress in Floor Area Sprinklered Throughout Forming Part of Sentence 3.3.1.5.(1) Occupancy of Room or Suite Maximum Area of Room or Suite, m2 Group A 200 Group B, Division 1 100 Group B, Division 2 or 3 sleeping rooms 100 other than sleeping rooms 200 Group C 150(1) Group D 300 Group E 200 Group F, Division 2 200 Group F, Division 3 300 Notes to Table 3.3.1.5.-B: (1) See Article 3.3.4.4. for dwelling units. (3) Every room containing an assembly occupancy serving a hotel, and located in the building containing the hotel, shall be provided with no fewer than (a) three separate egress doorways from the room where the occupant load is more than 600 persons, and (b) four separate egress doorways from the room where the occupant load is more than 1 000 persons (4) Each egress doorway in Sentence (4) shall be considered as contributing not more than, (a) one-third of the required width where three egress doorways are required, and (b) one-fourth of the required width where four egress doorways are required.

This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.