3.3.1.11.Door Swing
(1) Except as permitted by Sentence (5) and Article 3.3.1.12., a door that opens into a corridor or other facility
providing access to exit from a suite or room not located within a suite, shall swing on a vertical axis.
(2) Except as permitted by Article 3.3.1.12., a door that opens into a corridor or other facility providing access to exit
from a room or suite shall swing in the direction of travel to the exit if the room or suite is used or intended for
(a) an occupant load more than 60,
(b) a high-hazard industrial occupancy, or
(c) a hazardous classroom in an elementary or secondary school.
(3) Every door that divides a corridor that is not wholly contained within a suite shall swing on a vertical axis in the
direction of travel to the exit where the corridor provides access to exit for
(a) an occupant load more than 60,
(b) a high-hazard industrial occupancy,
(c) a hazardous classroom in an elementary or secondary school,
(d) a Group B, Division 2 or 3 occupancy, or
(e) a retirement home.
(4) If a pair of doors is installed in a corridor that provides access to exit in both directions, the doors shall swing in
opposite directions, with the door on the right hand side swinging in the direction of travel to the exit.
(5) Doors that serve individual storage spaces not more than 28 m2 in area in self-service storage buildings need not
conform to Sentence (1).
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.