9.20.8.5.Projection of Masonry Veneer Beyond Supporting Members
(1) Masonry veneer of solid masonry units resting on a bearing support shall not project more than one-third of the
thickness of the veneer. (See Note A-9.20.8.5.(1))
(2) Where the masonry veneer described in Sentence (1) is rough stone masonry,
(a) the projection shall be measured as the average projection of the units, and
(b) the thickness of the veneer shall be measured as the average thickness of the veneer.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.