9.20.9.1.Joints to be Offset or Reinforced
(1) Vertical joints in adjacent masonry courses shall be offset unless each wythe of masonry is reinforced with the
equivalent of not less than 2 corrosion-resistant steel bars of 3.76 mm diam placed in the horizontal joints at vertical
intervals not exceeding 460 mm.
(2) Where joints in the reinforcing referred to in Sentence (1) occur, the bars shall be lapped not less than 150 mm.
← Previous9.20.8.5. Projection of Masonry Veneer Beyond Supporting MNext →9.20.9.2. Bonding or Tying of Other Than Masonry Veneer
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.