What STC rating is required between dwelling units in Ontario?
Walls and floors separating one dwelling unit from another, or from common spaces, must achieve a sound transmission class (STC) of at least 50. Assemblies next to elevator shafts or refuse chutes require STC 55.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
STC 50 applies to demising walls in duplexes, townhouses, and between a basement apartment and the main unit, including the floor assembly, which is the hardest part of most conversions. Ratings come from tested assemblies, such as those catalogued in Supplementary Standard SB-3, so you must build the listed assembly exactly: layer counts, insulation, and resilient channels all matter. Note that STC only addresses airborne sound; footstep (impact) noise is not regulated but drives most tenant complaints, so consider it anyway.
Where two homes share a wall or floor, the construction must block enough airborne noise to score at least STC 50, roughly meaning loud speech next door is inaudible. Near elevators or garbage chutes, the bar rises to 55.