What are the minimum openable window areas for natural ventilation in Ontario?
Where rooms rely on natural ventilation, most habitable rooms need an unobstructed openable area of at least 0.28 m2 (3 sq ft), bathrooms about 0.09 m2, and unfinished basements openings totalling 0.2 percent of floor area. Mechanical ventilation can substitute.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
Since new Ontario homes must have mechanical ventilation, these natural ventilation minimums matter mostly for seasonal buildings, unconditioned spaces and older-building renovations. Only the openable, unobstructed portion of a window counts, so a large fixed picture window contributes nothing; check the actual clear opening of casements and sliders. Do not confuse this with the separate bedroom egress window rule of 0.35 m2 in Subsection 9.9.10, which governs escape rather than air. When finishing a basement, previously adequate ventilation openings often get drywalled over and must be replaced by mechanical means.
If a room has no mechanical ventilation, its windows must actually open wide enough to air it out, roughly 0.28 square metres of clear opening for bedrooms and living rooms. Fixed glass does not count, only the part that opens.
Get answers like this for any code question
BUILDAiD Assist searches the building code and answers in plain English with exact citations — in seconds.
This page is provided for general information. Building code requirements depend on your specific project, occupancy and municipality, and code editions change. Always verify requirements against the current Ontario Building Code and confirm with your local building department.