What are the exhaust fan requirements for bathrooms and kitchens in Ontario?
Intermittent exhaust fans must provide at least 25 L/s (about 50 cfm) in bathrooms and 50 L/s (about 100 cfm) in kitchens; continuously running alternatives may use lower rates. All exhausts must duct directly outdoors, never into attics.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
The two chronic failures here are termination and duct quality. Fans dumped into attics or soffit cavities saturate insulation and rot sheathing; code requires a dedicated exterior hood with backdraft damper. Runs through unheated space need insulation and slope so condensation drains outward. Kitchen range hoods over gas appliances and high-output cooking may warrant more than the minimum, but very large hoods raise makeup-air and combustion-spillage concerns for fuel-fired appliances. Choose quiet fans, ideally rated 1.0 sone or less, because loud fans simply never get switched on.
Every bathroom needs a fan pushing at least about 50 cfm, and kitchens about 100 cfm, with the duct running all the way outside. Venting a fan into the attic is a guaranteed recipe for mould and rot.