9.27.3.4.Insulating Sheathing in Lieu of Sheathing Membrane
(1) Where non-wood-based rigid exterior insulating sheathing, or exterior insulating sheathing with an integral
sheathing membrane is installed, a separate sheathing membrane is not required.
(2) Where insulating sheathing is installed as provided in Sentence (1),
(a) sheathing panels subject to moisture deterioration shall be sealed at all joints, and
(b) the joints of sheathing panels not subject to moisture deterioration shall be
(i) sealed at all joints, or
(ii) lapped or tongue and groove, and detailed to ensure drainage of water to the exterior.
(See Note A-9.27.3.4.(2))
← Previous9.27.3.3. Required Sheathing Membrane and InstallationNext →9.27.3.5. Sheathing Membranes in Lieu of Sheathing
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.