PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.27.3.5.Sheathing Membranes in Lieu of Sheathing
(1) Except as provided in Article 9.27.3.6., where no sheathing is used, at least 2 layers of sheathing membrane shall be
applied beneath the cladding. (See Article 9.23.17.1. and Note A-9.27.3.5.(1))
(2) All joints in the sheathing membrane required in Sentence (1) shall occur over framing, and the membrane shall be
fastened to the framing with roofing nails or staples spaced not more than 150 mm along the edges of the outer layer of
sheathing membrane.
(3) Wall sheathing is permitted to be used in lieu of one layer of sheathing membrane required in Sentence (1), and the
thickness need not conform to Table 9.23.17.2.-A.
This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.
← Previous9.27.3.4. Insulating Sheathing in Lieu of Sheathing MembraNext →9.27.3.6. Face Sealed Cladding (See Note A-9.27.3.6.)
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.