9.20.8.2.Cavity Walls Supporting Framing Members

(1) Floor joists supported on cavity walls shall be supported on solid masonry units not less than 57 mm high. (2) Floor joists described in Sentence (1) shall not project into the cavity. (3) Roof and ceiling framing members bearing on cavity walls shall be supported on (a) solid masonry units not less than 57 mm high that bridge the full thickness of the wall, or (b) a wood plate not less than 38 mm thick, bearing not less than 50 mm on each wythe.

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.