PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.20.8.1.Capping of Hollow Masonry Walls
(1) Except as permitted in Sentence (2), loadbearing walls of hollow masonry units supporting roof or floor framing
members shall be capped with not less than 50 mm of solid masonry or have the top course filled with concrete.
(2) Capping required in Sentence (1) may be omitted where the roof framing is supported on a wood plate not less than
38 mm by 89 mm.
← Previous9.20.7.5. Chases or Recesses Cut into WallsNext →9.20.8.2. Cavity Walls Supporting Framing Members
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.