PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.20.13.12.Drips Beneath Window Sills
(1) Except for wall openings located less than 150 mm above ground level, where a concealed flashing is not installed
beneath window and door sills, such sills shall be provided with an outward slope and a drip located not less than 25 mm
from the wall surface.
← Previous9.20.13.11. Caulking at Door and Window FramesNext →9.20.14.1. Laying Temperature of Mortar and Masonry
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.