9.20.10.1.Lateral Support Required
(1) Masonry walls shall be laterally supported by floor or roof construction or by intersecting masonry walls or
buttresses.
(2) The spacing of supports required in Sentence (1) shall be not more than
(a) 20 times the wall thickness for all loadbearing walls and exterior non-loadbearing walls, and
(b) 36 times the wall thickness for interior non-loadbearing walls.
(3) In applying Sentence (2), the thickness of cavity walls shall be taken as the greater of
(a) two-thirds of the sum of the thicknesses of the wythes, or
(b) the thickness of the thicker wythe.
(4) Floor and roof structural elements providing lateral support for walls as required in Sentence (1) shall be constructed
to transfer lateral loads to walls or buttresses approximately at right angles to the laterally supported walls.
← Previous9.20.9.6. Reinforcing for Glass BlockNext →9.20.11.1. Anchorage to Floor or Roof Assemblies where Maso
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.