PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.11.1.3.Compliance with Required Ratings
(1) Compliance with the required STC ratings shall be demonstrated through
(a) measurements carried out in accordance with Sentence 9.11.1.2.(1), or
(b) the construction of separating assemblies conforming to Table 1 or 2 of MMAH Supplementary Standard SB-3,
“Fire and Sound Resistance Tables,” as applicable.
(2) Compliance with the required ASTC ratings shall be demonstrated through
(a) measurements or calculations carried out in accordance with Sentence 9.11.1.2.(2), or
(b) the construction of separating assemblies conforming to Table 1 or 2 of MMAH Supplementary Standard SB-3,
“Fire and Sound Resistance Tables,” as applicable, that have an STC rating of not less than 50 in conjunction with
flanking assemblies constructed in accordance with Article 9.11.1.4. (See Note A-9.11.1.3.(2)(b))
← Previous9.11.1.2. Determination of Sound Transmission RatingsNext →9.11.1.4. Adjoining Constructions (See Note A-9.11.1.4.)
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.