PART 7 — PLUMBINGUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
7.6.2.5A.Backflow from Buildings with a Solar Domestic Hot Water System
(See Note A-7.6.2.5A.)
(1) Except as permitted by Sentence (2) and as provided in Sentences (3) and (4), a potable water system shall be
protected against backflow where the heat transfer loop of a solar domestic hot water system is directly connected to the
potable water system.
(2) Where the heat transfer loop of the solar domestic hot water system consists of direct flow-through of potable water
only, protection against backflow is not required.
(3) A potable water system that is directly connected to the heat transfer loop of a solar domestic hot water system that
serves a residential occupancy within the scope of Part 9 shall be provided with a backflow preventer selected in
accordance with CAN/CSA-F379.1, “Packaged solar domestic hot water systems (liquid-to-liquid heat transfer) for all-
season use.”
(4) Where a solar domestic hot water system includes a single wall heat exchanger and contains only a relatively
harmless heat transfer fluid as described in CAN/CSA-F379.1, “Packaged solar domestic hot water systems (liquid-to-
liquid heat transfer) for all-season use”, the backflow prevention required in Sentence (1) is permitted to be a dual check
valve backflow preventer conforming to CSA B64.3, “Dual Check valve backflow preventers with atmospheric port
(DCAP)”.
← Previous7.6.2.4. Backflow from Fire Protection SystemsNext →7.6.2.6. Premise Isolation (See Note A-7.6.2.6.)
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.