OBC DIVISION B · PART 9 · SECTION 9.1 — GENERAL

When does a building need Part 3 design instead of Part 9 in Ontario?

You must design to Parts 3 to 6 when a building exceeds 3 storeys or 600 m2 in building area, or contains assembly, care, detention, or high-hazard industrial occupancies, which Part 9 never covers.

Code reference
Buildings that exceed 3 storeys in building height or 600 m2 in building area, or that contain Group A (assembly), Group B (care, treatment or detention), or Group F1 (high-hazard industrial) major occupancies, fall outside Part 9 and must comply with the applicable requirements of Parts 3, 4, 5 and 6 of Division B.
OBC Division B, Subsection 9.1.1.

Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.

What this means in practice

Crossing any single threshold pulls the whole building out of Part 9: a fourth storey, a footprint over 600 m2, or one restaurant, daycare, or care occupancy inside. Part 3 brings fire-resistance ratings, spatial separation calculations, and barrier-free design; Part 4 requires engineered structural design; Part 5 governs the building envelope. Budget and schedule change significantly, so confirm classification with your municipality early. Even within Part 9, individual elements outside prescriptive limits still need Part 4 engineering.

Plain language

If your building gets too big, too tall, or includes uses like a restaurant, daycare, or care home, the simplified house rules no longer apply. You then need the full code and licensed designers or engineers.