What gas-proofing is required between an attached garage and the house in Ontario?
The wall and ceiling between an attached garage and the dwelling must form a continuous air barrier against carbon monoxide and fumes, with any connecting doorway fitted with a tight, weatherstripped, self-closing door, and no door opening into a sleeping room.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
This is a life-safety detail aimed at carbon monoxide, and it is scrutinized at insulation and final inspections. Tape or seal the poly or airtight drywall across the whole shared wall and ceiling, foam every wire, pipe and duct penetration, and remember ducts should not serve the garage from the house system. The man-door needs functioning self-closing hardware, which owners notoriously disable. Pair the sealed separation with the carbon monoxide alarm requirements that apply to dwellings with attached garages, since the alarm is the backup, not the primary defence.
The wall between your garage and your home has to be sealed airtight so car exhaust cannot seep inside, and the connecting door must close itself firmly. Carbon monoxide is invisible, so the code treats this joint seriously.