What clearances and damper requirements apply to fireplaces in Ontario?
Combustible trim and mantels must keep prescribed distances from the fireplace opening, on the order of 150 mm (6 in.) for flush trim and more for projecting shelves. Every fireplace needs a damper that can close off the throat or flue, and site-built fireplaces need combustion air provisions.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
The pattern to remember is that the closer and more projecting the combustible element, the larger the clearance: flush tile-to-wood joints near the opening are the usual violation, followed by chunky wood mantels installed too low. Dampers matter for both safety and energy, since an open flue is a running hole in the building envelope; glass doors and exterior combustion air ducts address the same problem. Factory-built fireplaces override these site-built rules with their listed installation instructions, which become the code requirement for that unit, so keep the manual for inspection.
Wood trim needs breathing room around a fireplace opening, roughly 150 mm for flat trim and more for a shelf-style mantel that sticks out. And every fireplace needs a working damper, a metal flap that shuts the chimney when you are not burning so your heated air does not escape.