How far apart must exits be located under the Ontario Building Code?
Where multiple exits are required they must be remote from each other, generally separated by at least one half of the maximum diagonal dimension of the floor area, though the required separation need not exceed 9 m in certain corridor-served layouts.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
Remoteness is checked on the floor plan by drawing the maximum diagonal of the floor area, then measuring between exit doors or stair enclosures. Scissor stairs in a single shaft raise remoteness questions and need careful separation detailing to count as independent exits. Core-and-shell towers with compact cores often rely on the corridor-connection relaxation, so document the corridor rating and configuration that justifies the measured separation.
Two exits close together are really one exit in a fire. The Code makes them stand far apart, roughly half the room's longest diagonal, so smoke or flames at one door still leaves the other reachable.