What size footing does a basement column need in Ontario?
Column footings come from the OBC footing tables: for columns spaced about 3 m (10 ft) apart, minimum areas are roughly 0.4 m² supporting one floor, 0.75 m² for two and 1.0 m² for three, on adequate soil, with thickness at least 100 mm and not less than the footing projection.
Paraphrased for clarity — open this provision in the BUILDAiD Library for the exact wording.
A column collects half the beam span on each side, so spacing the posts farther apart than the tabulated assumption means the footing area must grow proportionally. Practical pitfalls: pads poured thin and unreinforced under heavy point loads, footings cast on disturbed trench backfill near the sump or plumbing runs, and finished-basement renovations that move a post onto plain slab, since a 75 mm slab is not a footing. Interior column footings in a heated basement do not need frost depth, but columns for decks and porches outside do.
Each basement post needs its own concrete pad below the floor, sized to the weight it carries, roughly 0.4 to 1.0 square metres depending on how many floors sit above. The basement slab itself is not strong enough to act as that pad.