PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code

9.9.6.4.Door Action

(1) Except as provided in Sentences (4) and (5), required exit doors and doors in required means of egress, except doors in means of egress within dwelling units, shall swing on the vertical axis. (2) Except as provided in Sentence (5), breakaway sliding doors, installed as required exit doors or required doors in means of egress, shall be identified as swinging doors by means of a label or decal affixed to the door. (3) Revolving doors shall comply with Article 3.4.6.15. (4) Movable partitions used to separate a public corridor from an adjacent business and personal services occupancy or a mercantile occupancy need not conform to Sentence (1), provided the partitions are not located in the only means of egress. (See Note A-3.3.1.12.(3)) (5) Exit doors need not conform to Sentence (1) or (2), where (a) the doors serve accessory buildings where life safety is not adversely affected, (b) the doors serve storage garages or other accessory buildings serving not more than one dwelling unit, or (c) the doors (i) serve storage suites of not more than 28 m2 in gross area that are in warehousing buildings of not more than one storey, and (ii) open directly to the exterior at ground level.

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.