9.26.8.3.Securing of Tabs
(1) Shingle tabs shall be secured with cold application cement applied at the rate of not less than 0.5 L/m² of cemented
area, or hot application asphalt applied at the rate of 1 kg/m² of cemented area.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.