9.26.2.3.Nails

(1) Nails used for roofing shall be corrosion-resistant roofing or shingle nails conforming to (a) ASTM F1667, “Standard Specification for Driven Fasteners: Nails, Spikes, and Staples,” or (b) CSA B111, “Wire Nails, Spikes and Staples.” (2) Nails shall have sufficient length to penetrate through or 12 mm into, roof sheathing. (3) Nails used with asphalt roofing shall have a head diameter of not less than 9.5 mm and a shank thickness of not less than 2.95 mm. (4) Nails used with wood shingles or shakes shall have a head diameter of not less than 4.8 mm and a shank thickness of not less than 2.0 mm and shall be stainless steel, aluminum or hot-dipped galvanized. (See Note A-9.26.2.3.(4))

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.