PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.24.3.1.Installation of Runners
(1) Runners shall be provided at the tops and bottoms of walls.
(2) Runners required in Sentence (1) shall be securely attached to the building at approximately 50 mm from the ends,
and at intervals of not more than 600 mm o.c. for interior walls and 300 mm o.c. for exterior walls.
(3) Fasteners used for attachment described in Sentence (2) shall consist of the equivalent of 63 mm nails or 25 mm
screws.
(4) Studs at openings and which are not full wall height shall be supported by a runner at the ends of the studs, securely
fastened to the full length studs at the sides of the opening.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.