PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code

9.24.2.5.Size and Spacing of Studs in Exterior Walls

(1) The size and spacing of non-loadbearing steel studs for exterior walls shall conform to Table 9.24.2.5. Table 9.24.2.5. Size and Spacing of Steel Studs for Non-Loadbearing Exterior Walls Forming Part of Sentence 9.24.2.5.(1) Maximum Stud Length, m Minimum Stud Size, mm Minimum Metal Thickness, mm Spacing of Studs 300 mm o.c. 400 mm o.c. 600 mm o.c. 30 × 91 0.53 3.0 2.4 — 30 × 91 0.69 3.3 2.7 2.4 30 × 91 0.85 3.6 3.0 2.7 30 × 91 1.0 4.0 3.3 3.0

This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.

Understand this provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.