9.22.3.1.Thickness of Walls
(1) Except as provided in Sentence (2), the thickness of the back and sides of a fireplace, including the thickness of any
firebrick liner, shall be not less than 190 mm where a metal liner or a firebrick liner less than 51 mm thick is used.
(2) When a steel fireplace liner is used with an air circulating chamber surrounding the firebox, the back and sides of the
fireplace shall consist of
(a) solid masonry units not less than 90 mm thick, or
(b) hollow masonry units not less than 190 mm thick.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.