PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.22.10.2.Installation
(1) The installation of fireplace inserts and hearth-mounted stoves vented through the throat of a fireplace shall conform
to CSA B365, “Installation Code for Solid-Fuel-Burning Appliances and Equipment.”
(2) Fireplace inserts and hearth-mounted stoves vented through the throat of a fireplace described in Sentence (1) may
be installed in existing fireplaces only if a minimum thickness of 190 mm of solid masonry is provided between the
smoke chamber and any existing combustible materials, unless the insert is listed for lesser clearances.
(3) A fireplace insert installed in a masonry fireplace shall have
(a) a listed metal chimney liner installed from the insert collar to the top of the chimney, or
(b) a direct sealed connection to the chimney flue where such provision is part of an insert conforming to Sentence
9.22.10.1.(1).
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.