PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.20.17.6.Anchoring of Roof Framing to Top of Flat Insulating Concrete
Form Walls
(1) Roof framing supported on the top of flat insulating concrete form walls shall be fixed to the top plates, which shall
be anchored to the wall with anchor bolts
(a) not less than 12.7 mm in diameter, and
(b) spaced not more than 1 200 mm o.c.
(2) The anchor bolts described in Sentence (1) shall be placed in the centre of the flat insulating concrete form wall and
shall be embedded no less than 100 mm into the concrete.
(3) Attachment of roof framing to wood top plates shall be in accordance with Table 9.23.3.4.
This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.
← Previous9.20.17.5. Framing Supported on Flat Insulating Concrete FoNext →9.20.17.7. Protection from Precipitation and Damage
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.