PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.20.12.3.Corbelling for Masonry Veneer
(1) Masonry veneer resting on a bearing support shall not project more than 25 mm beyond the supporting base where
the veneer is not less than 90 mm thick, and 12 mm beyond the supporting base where the veneer is less than 90 mm
thick.
(2) In the case of rough stone veneer, the projection, measured as the average projection of the stone units, shall not
exceed one-third the bed width beyond the supporting base.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.