9.20.11.5.Anchoring Masonry Cornices, Sills and Trim to Masonry Walls
(1) Cornices, sills or other trim of masonry material which project beyond the wall face shall have not less than 65% of
their mass, but not less than 90 mm, within the wall or shall be adequately anchored to the wall with corrosion-resistant
anchors.
← Previous9.20.11.4. Anchoring Wood-Frame Roof Systems to Masonry WalNext →9.20.11.6. Anchoring to Masonry Piers
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.