9.20.1.2.Earthquake Reinforcement (See Note A-9-20.1.2.)
(1) In locations where the seismic spectral acceleration, Sa(0.2), is greater than 0.55, loadbearing elements of masonry
buildings more than 1 storey in building height shall be reinforced with not less than the minimum amount of
reinforcement as required by Subsection 9.20.15.
(2) In locations where the seismic spectral acceleration, Sa(0.2), is greater than 0.35, but less than or equal to 0.55,
loadbearing elements of masonry buildings 3 storeys in building height shall be reinforced with not less than the
minimum amount of reinforcement as required by Subsection 9.20.15.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.