9.10.9.4.Floor Assemblies
(1) Except as permitted in Sentences (2) to (4), all floor assemblies shall be constructed as fire separations.
(2) Floor assemblies contained within dwelling units need and within houses with a secondary suite need not be
constructed as fire separations.
(3) Floor assemblies for which no fire-resistance rating is required by Subsection 9.10.8. and floors of mezzanines not
required to be counted as storeys in Articles 9.10.4.1. and 9.10.4.2. need not be constructed as fire separations.
(4) Where a crawl space is not required by Article 9.10.8.9. to be constructed as a basement, the floor above it need not
be constructed as a fire separation.
← Previous9.10.9.3. Openings to be Protected With ClosuresNext →9.10.9.5. Interconnected Floor Spaces
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.