7.2.3.2.Interceptors
(1) Interceptors shall be designed so that they can be readily cleaned.
(2) Grease interceptors shall be designed so that they do not become air bound.
(3) Grease interceptors shall be selected and installed in conformance with
(a) CSA B481.0, “Material, design, and construction requirements for grease interceptors,” and
(b) CSA B481.3, “Sizing, selection, location, and installation of grease interceptors.”
(See Note A-7.2.3.2.(3))
(4) Where a grease interceptor is required by Sentence 7.4.4.3.(1), the interceptor shall conform to
(a) CSA B481.1, “Testing and rating of grease interceptors using lard,” or
(b) CSA B481.2, “Testing and rating of grease interceptors using oil.”
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.