3.7.4.7.Plumbing Fixtures for Business and Personal Services Occupancies
(1) Except as provided in Sentence (2), the number of water closets required for business and personal services
occupancies shall conform to Table 3.7.4.7.
(2) Not more than one water closet to serve both sexes need be provided in a Group D occupancy having an occupant
load of not more than 10 persons.
Table 3.7.4.7.
Water Closets for Business and Personal Services Occupancies
Forming Part of Sentence 3.7.4.7.(1)
Number of Persons Minimum Number of Water Closets
of Each Sex for Each Sex
up to 9 1
10 to 24 2
25 to 49 3
50 to 74 4
75 to 100 5
6 plus 1 for each additional increment of
over 100
30 persons of each sex in excess of 100
This provision includes a table — formatting is preserved from the source; refer to the official code for the authoritative layout.
← Previous3.7.4.6. Plumbing Fixtures for Other Residential OccupancNext →3.7.4.8. Plumbing Fixtures for Mercantile Occupancies
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.