PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
3.6.5.6.Clearance of Ducts and Plenums
(1) The clearance of furnace plenums from combustible material shall conform to the requirements of the appropriate
standards referenced in Sentence 6.2.1.5.(1).
(2) If the plenum clearance required in accordance with Sentence (1) is not more than 75 mm, the clearance between a
supply duct and combustible material shall be not less than
(a) the required plenum clearance within a horizontal distance of 450 mm from the plenum, and
(b) 12 mm at a horizontal distance of 450 mm or more from the plenum, except that this clearance is permitted to be
reduced to zero beyond a bend or offset in the duct sufficiently large to shield the remainder of the supply duct from
direct radiation from the furnace heat exchanger.
(See Note A-3.6.5.6.(2))
(3) If the plenum clearance required in accordance with Sentence (1) is more than 75 mm but not more than 150 mm,
the clearance between a supply duct and combustible material shall be not less than
(a) the required plenum clearance within a horizontal distance of 1 800 mm from the plenum, and
(b) 12 mm at a horizontal distance of 1 800 mm or more from the plenum, except that this distance is permitted to be
reduced to zero beyond a bend or offset in the duct sufficiently large to shield the remainder of the supply duct from
direct radiation from the furnace heat exchanger.
(See Note A-3.6.5.6.(3))
(4) If the plenum clearance required in accordance with Sentence (1) is more than 150 mm, the clearance between a
supply duct and combustible material shall be not less than
(a) the required plenum clearance within a horizontal distance of 1 000 mm from the plenum,
(b) 150 mm within a horizontal distance between 1 000 mm and 1 800 mm from the plenum, and
(c) 25 mm at a horizontal distance of 1 800 mm or more from the plenum, except that this distance is permitted to be
reduced to 8 mm beyond a bend or offset in the duct sufficiently large to shield the remainder of the supply duct
from direct radiation from the furnace heat exchanger.
(See Note A-3.6.5.6.(4))
(5) If a register is installed in a floor directly over a pipeless furnace, a double-walled register box with not less than
100 mm between walls, or a register box with the warm-air passage completely surrounded by the cold-air passage, shall
be permitted instead of the clearances listed in Sentences (2) to (4).
← Previous3.6.5.5. Insulation and CoveringsNext →3.6.5.7. Supply, Return, Intake and Exhaust-Air Openings
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.