PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
3.4.5.3.Signs for Stairs and Ramps at Exit Level
(1) In a building more than 2 storeys in building height, any part of an exit ramp or stair that continues up or down past
the lowest exit level shall be clearly marked by a sign indicating that it does not lead to an exit.
(2) An exit stair serving a building more than 6 storeys in building height shall be clearly marked by signs indicating
that it does not lead to an exit at the roof level. (See Note A-3.4.5.3.(2))
← Previous3.4.5.2. Exit Signs with Tactile InformationNext →3.4.6.1. Surface Finish of Ramps and Stairs
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.