3.4.1.2.Separation of Exits
(1) Except as permitted by Sentence (2), if more than one exit is required from a floor area, each exit shall be separate
from every other exit leading from that floor area.
(2) If more than 2 exits are provided from a floor area, exits are permitted to converge in conformance with Sentence
3.4.3.1.(2), provided the cumulative capacity of the converging exits does not contribute more than 50% of the total
required exit width for the floor area.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.