3.2.2.8.Exceptions for Major Occupancies
(1) In a building in which the aggregate area of all major occupancies in a particular Group or Division is not more than
10% of the floor area of the storey in which they are located, these major occupancies need not be considered as major
occupancies for the purposes of this Subsection, provided they are not classified as Group F, Division 1 or 2 occupancies.
(2) For the purposes of Sentence (1), a retirement home is deemed to be a separate major occupancy.
(3) A helicopter landing area on the roof of a building need not be considered a major occupancy for purposes of
Subsection 3.2.2. where such landing area is not more than 10% of the area of the roof.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.