PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
3.2.2.10.Streets
(1) Every building shall face a street located in conformance with the requirements of Articles 3.2.5.4 and 3.2.5.5 for
access routes.
(2) For the purposes of Subsections 3.2.2. and 3.2.5. an access route conforming to Subsection 3.2.5. is permitted to be
considered as a street.
(3) A building conforming to Article 3.2.2.51. or 3.2.2.60. is considered to face one street, where
(a) not less than 25% of the building perimeter is located within 15 m of a street or streets, or
(b) not less than 10% of the building perimeter is located within 15 m of a street or streets, provided the exterior
cladding conforms to Sentence 3.1.4.8.(2).
(4) A building is considered to face 2 streets provided not less than 50% of the building perimeter is located within
15 m of the street or streets.
(5) A building is considered to face 3 streets provided not less than 75% of the building perimeter is located within
15 m of the street or streets.
(6) Enclosed spaces, tunnels, bridges and similar structures, even though used for vehicular or pedestrian traffic, are not
considered as streets for the purpose of this Part.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.