PART 3 — FIRE PROTECTION, OCCUPANT SAFETY AND ACCESSIBILITYUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
3.1.5.24.Wood Decorative Cladding
(1) On buildings required to be of noncombustible construction, decorative wood cladding is permitted to be used on the
exterior fascias and soffits of marquees or canopies on the building face of a storey having direct access to a street or
access route, provided the wood cladding is fire-retardant-treated wood that has been conditioned in conformance with
ASTM D2898, “Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing,” before
being tested in accordance with CAN/ULC-S102, “Standard Method of Test for Surface Burning Characteristics of
Building Materials and Assemblies.”
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.