2.2.1.7.Firewalls
(1) A firewall that separates a building or buildings with floor areas containing a Group G, Division 1 major occupancy
shall be constructed as a fire separation of noncombustible construction having a fire-resistance rating not less than 4 h.
(2) A firewall that separates a building or buildings with floor areas containing a Group G major occupancy and a
major occupancy prohibited by Article 2.2.1.2. shall be constructed as a fire separation of noncombustible construction
having a fire-resistance rating not less than 4 h.
(3) Firewalls shall conform to the requirements of Articles 3.1.10.1. and 3.1.10.3. to 3.1.10.7., and Sentence
3.1.10.2.(3).
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.