SB-8 Design, Construction and
Installation of Anchorage Systems
for Fixed Access Ladders
Design
The design, construction and installation of the anchorage system for a fixed access ladder shall be capable of withstanding
the anticipated loads from the ladder.
The following are the minimum criteria to be used in the design:
• The minimum design live load should be two loads of 1.1 kN each concentrated between any two consecutive
attachments.
• Other loads, such as concentrated loads, loads due to ice, wind, rigging and impact, and dead loads, must be
considered in the design.
• A safety factor of at least 4:1 should be applied in designing components for normal usage, and at least 10:1 for
components supporting fall-arrest systems.
Attachment and Anchorage
The attachment method must be rated for the intended structural service and take into consideration the type of wall or
member which will support the ladder.
• Expansion anchors should be avoided with masonry walls. Since anchor manufacturers’ pull-out ratings are usually
given for poured concrete walls, they cannot be reliably attained in masonry walls.
• Through-bolted connections, or equivalent, must be used for masonry walls, and other walls for which there is no
anchor manufacturers’ pull-out rating. Generally, through-bolted connections should be used wherever practicable.
• Attachment and anchor bolts should have a minimum diameter of 12 mm.
• Maximum spacing of attachment points for a steel ladder with side rails shall be 3 m.
• For different materials or extra loads, this maximum spacing must be adjusted in accordance with recognized design
practice.
To provide an improved margin of safety, there should be two means of anchoring the top of the ladder. This may be
accomplished by fastening the side rail extension above the top of the access/egress level to the roof.
If a ladder is to be attached to an existing wall, the structural soundness of the wall must be investigated to ensure it is
capable of supporting the ladder.
2024MMAH Supplementary Standard SB-8
Page 2 • SB-8
Ministry of Municipal Affairs and Housing
Building and Development Branch
MMAH Supplementary Standard SB-9
MMAH Supplementary Standard SB-9
Requirements for Soil Gas Control
January 1, 2024
2024MMAH Supplementary Standard SB-9
COMMENCEMENT
MMAH Supplementary Standard SB-9 comes into force on the 1st day of January 2025.
© Copyright
©
Copyright King's Printer for Ontario 2024
All rights reserved.
Questions regarding copyright, including reproduction and distribution, may be directed to the Director,
Building and Development Branch of the Ministry of Municipal Affairs and Housing.
Understand any provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.