OBC VOLUME 2 · SUPPLEMENTARY STANDARD SB-8Updated for the 2024 Ontario Building Code

SB-8 — Design, Construction and Installation of Anchorage Systems

Supplementary Standard SB-8 ("Design, Construction and Installation of Anchorage Systems") forms part of Volume 2 of the 2024 Ontario Building Code. The full text is reproduced below with a linked table of contents.

On this page:
202420242024

2024MMAH Supplementary Standard SB-8

SB-8 Design, Construction and Installation of Anchorage Systems for Fixed Access Ladders Design The design, construction and installation of the anchorage system for a fixed access ladder shall be capable of withstanding the anticipated loads from the ladder. The following are the minimum criteria to be used in the design: • The minimum design live load should be two loads of 1.1 kN each concentrated between any two consecutive attachments. • Other loads, such as concentrated loads, loads due to ice, wind, rigging and impact, and dead loads, must be considered in the design. • A safety factor of at least 4:1 should be applied in designing components for normal usage, and at least 10:1 for components supporting fall-arrest systems. Attachment and Anchorage The attachment method must be rated for the intended structural service and take into consideration the type of wall or member which will support the ladder. • Expansion anchors should be avoided with masonry walls. Since anchor manufacturers’ pull-out ratings are usually given for poured concrete walls, they cannot be reliably attained in masonry walls. • Through-bolted connections, or equivalent, must be used for masonry walls, and other walls for which there is no anchor manufacturers’ pull-out rating. Generally, through-bolted connections should be used wherever practicable. • Attachment and anchor bolts should have a minimum diameter of 12 mm. • Maximum spacing of attachment points for a steel ladder with side rails shall be 3 m. • For different materials or extra loads, this maximum spacing must be adjusted in accordance with recognized design practice. To provide an improved margin of safety, there should be two means of anchoring the top of the ladder. This may be accomplished by fastening the side rail extension above the top of the access/egress level to the roof. If a ladder is to be attached to an existing wall, the structural soundness of the wall must be investigated to ensure it is capable of supporting the ladder.

2024MMAH Supplementary Standard SB-8

Page 2 • SB-8 Ministry of Municipal Affairs and Housing Building and Development Branch MMAH Supplementary Standard SB-9 MMAH Supplementary Standard SB-9 Requirements for Soil Gas Control January 1, 2024

2024MMAH Supplementary Standard SB-9

COMMENCEMENT MMAH Supplementary Standard SB-9 comes into force on the 1st day of January 2025. © Copyright © Copyright King's Printer for Ontario 2024 All rights reserved. Questions regarding copyright, including reproduction and distribution, may be directed to the Director, Building and Development Branch of the Ministry of Municipal Affairs and Housing.

Understand any provision in seconds

BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.

Try BUILDAiD Beta

Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.