9.9.9.1.Travel Limit to Exits or Egress Doors
(1) Except as provided in Sentences (2) and (3), every dwelling unit containing more than 1 storey shall have exits or
egress doors located so that it shall not be necessary to travel up or down more than 1 storey to reach a level served by
(a) an egress door to a public corridor, enclosed exit stair or exterior passageway, or
(b) an exit doorway not more than 1.5 m above adjacent ground level.
(2) Where a dwelling unit is not located above or below another suite, the travel limit from a floor level in the dwelling
unit to an exit or egress door may exceed 1 storey where that floor level is served by an openable window or door
(a) providing an unobstructed opening of not less than 1 m in height and 0.55 m in width, and
(b) located so that the sill is not more than
(i) 1 m above the floor, and
(ii) 7 m above adjacent ground level.
(3) The travel limit from a floor level in a dwelling unit to an exit or egress door may exceed 1 storey where that floor
level has direct access to a balcony.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.