9.9.7.2.Means of Egress from Suites
(1) Except as required in Sentence 9.9.9.3.(1), each suite in a floor area occupied by more than one suite shall have
(a) an exterior exit doorway,
(b) a doorway to a public corridor, or
(c) a doorway to an exterior passageway.
(2) Except as provided in Sentences 9.9.7.3.(1) and 9.9.8.2.(2), from the point where a doorway described in
Clause(1)(b) or (c) enters the public corridor or exterior passageway, it shall be possible to go in opposite directions to
each of 2 separate exits.
← Previous9.9.7.1. Egress from Roof Area, Podiums, Terraces, PlatfoNext →9.9.7.3. Dead-End Corridors
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.