PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.9.5.3.Obstructions in Public Corridors
(1) Except as permitted in Sentence (2), obstructions located within 1 980 mm of the floor shall not project horizontally
more than 100 mm into exit passageways, corridors used by the public or public corridors in a manner that would create a
hazard for visually impaired persons travelling adjacent to walls.
(2) The horizontal projection of an obstruction referred to in Sentence (1) is permitted to exceed 100 mm where the
obstruction extends to less than 680 mm above the floor. (See Note A-3.3.1.8.(2) and (3))
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.