9.9.11.5.Floor Numbering
(1) Arabic numerals indicating the assigned floor number shall be
(a) except in hotels, mounted permanently on the stair side of the wall at the latch side of doors to exit stair shafts,
(b) in hotels, mounted permanently on each side of the exit doors to the exit stair shaft,
(c) not less than 60 mm high, raised approximately 0.8 mm above the surface,
(d) located 1 500 mm from the finished floor and not more than 300 mm from the door, and
(e) contrasting in colour with the surface on which they are applied. (See Note A-9.9.11.5.(1)(e))
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.