PART 9 — HOUSING AND SMALL BUILDINGSUpdated for the 2024 Ontario Building Code
Try BUILDAiD Beta
9.38.3.2.Clearance
(1) At every opening in a wall made of logs in a horizontal position where shrinkage can occur there shall be a clearance
between the rough buck header and the lintel log of not less than 13 mm in width for each 300 mm of height to allow for
settlement.
Understand this provision in seconds
BUILDAiD Assist explains any article of the building code in plain English — with exact citations, exceptions and related requirements.
Code text is reproduced for reference from the Ontario Building Code (O. Reg. 163/24, 2024 Building Code Compendium). This page is provided for general information and is not an official copy. Always verify requirements against the official Ontario Building Code and confirm with your local building department.